ALUTHERMO OPTIMA
A reflective insulation material made thicker to comply with European standards. Mainly used on roofs or as a vapour barrier on walls. EPC & LABC certified.
HOW DOES IT WORK?
OPTIMA is composed of the following successive layers:
- A film of pure 30 microns thick aluminium, treated against oxidation
- A layer of bubbles of dry air enclosed in self-extinguishing polyethylene
- A moisture-proof polyester fiber
- A layer of bubbles of dry air enclosed in self-extinguishing polyethylene
- A film of pure 30 microns thick aluminium, treated against oxidation
The aluminium sheets reflect thermal radiation summer and winter, while the polyester wadding core and the dry, stable air trapped in the bubble film effectively slow the transfer of energy by conduction.
This thin, high-performance insulation material also offers an impermeable barrier to moisture and is vapour proof.
- EPC & LABC certified
- Insulation and vapour barrier all in one
- Easy to install as it is welded across its entire surface
- Multi-reflective and multi-layer with a reinforced thermal and acoustic performance
- Reduces thermal bridges
- Durable as pure aluminium
- 10-year warranty in association with Allianz Assurances
Dimensions of the roll | 1,20 x 15 m (± 2%) |
---|---|
Surface area per roll | 18 m² |
Weight | ± 1100 g/m² |
Thickness | ± 42 mm |
Operating temperature range | -55°C to +80°C |
Fire resistance classification | F |
Thermal core resistance | R = 1,07 m².K/W (EN 12667) |
Thermal resistance in horizontal flux | R = 2,37 m².K/W (EN 16012) (*) |
Thermal resistance in horizontal flux | U = 0,42 m².K/W (EN 16012) (*) |
Thermal conductivity | λ = 0,039 W/(m.K) (EN 12667) |
Thermal performance | Up to 29% more effective than 200 mm of mineral wool (**) |
Emissivity | < 0,05 (EN 16012) |
Acoustic attenuation | Rw (C ; Ctr) = 41 (-5 ; -13) dB |
Sd value | > 6000 m |
Thickness of the polyethylene film | 150 microns |
Number of the aluminium films | 2 |
Thickness of the polyester fiber | ± 37 mm |
Thickness of the outer aluminium film | 30 microns |
(*) Performance data only valid for the installation between 2 air gaps without direct contact (see installation instructions of the product).
(**) Thermal performance measured by the Eliosys laboratory, comparing the energy consumption of a structure insulated once with Aluthermo and once with 200 mm of mineral wool (λ 0.040 W/m.K.).
In the absence of consensus on the standard, this result is not considered in the calculation of the EPC or the obtaining of a subsidy. See the Eliosys test report.
Technical installation instruction
Different U-Value calculations
U-Value and Condensation Risk Calculations – Slope Roof
U-Value and Condensation Risk Calculations – Timber Frame, Cavity, Timber Frame
U-Value and Condensation Risk Calculations – Timber Frame, No Cavity
U-Value and Condensation Risk Calculations – Attic Roof
U-Value and Condensation Risk Calculations – Brick Facing Timber Frame
U-Value and Condensation Risk Calculations – Flat Roof
U-Value and Condensation Risk Calculations – Timber Frame, Lightweight Block
More calculations available on request.